Match the opening
Confirm the existing sleeve, wall opening, cabinet fit, and exterior grille. TTW and PTAC formats are not interchangeable.
OLMO • The hospitality collection
For guest rooms, thoughtful replacements, and the next chapter of your property.
Seamless in-wall cooling with remote, Smart Connect app control, Sleep Mode, Timer, Auto Restart, and a self-evaporative system. Quiet, efficient, and easy to live with.
The Olmo “Through The Wall” unit blends convenience, efficiency, and comfort in a sleek package. Control it from the couch with the remote—or from anywhere with Smart Connect on your phone. Ideal for bedrooms, living rooms, and offices.
| Model | OW-P08AC115WF |
|---|---|
| Power supply | 115V, 1Ph, 60Hz |
| Cooling capacity (Btu/h) | 8300 |
| CEER (Btu/h/W) | 10.6 |
| Cooling input (W) | 760 |
| Cooling current (A) | 7.8 |
| Heating type | Cooling only |
| Refrigerant | R32 |
| Indoor air flow, high / medium / low (CFM) | 270.0 / 232.9 / 202.9 |
| Indoor noise, high / medium / low (dB(A)) | 55.6 / 52.4 / 49.5 |
| Outdoor noise, high / medium / low (dB(A)) | 63.6/59.4/55.9 |
| Plug type | LCDI(5-15P) |
| Unit dimensions, W × D × H (in) | 24.21 × 20.28 × 14.53 |
| Packing dimensions, W × D × H (in) | 27.95x26.57x16.93 |
| Net / gross weight (lb) | 65.48/77.16 |
| Model | OW-P08HS115WF |
|---|---|
| Power supply | 115V, 1Ph, 60Hz |
| Cooling capacity (Btu/h) | 8000 |
| CEER (Btu/h/W) | 9.6 |
| Cooling input (W) | 750 |
| Cooling current (A) | 9.4 |
| Heating type | Electric heat strip |
| Electric heating capacity (Btu/h) | 4200 |
| Electric heating input (W) | 1220 |
| Refrigerant | R32 |
| Indoor air flow, high / medium / low (CFM) | 258.8 / 227.1 / 192.4 |
| Indoor noise, high / medium / low (dB(A)) | 58.7 / 55.4 / 52 |
| Outdoor noise, high / medium / low (dB(A)) | 63.5/59.7/55.9 |
| Plug type | LCDI(5-15P) |
| Unit dimensions, W × D × H (in) | 24.21 × 20.28 × 14.53 |
| Packing dimensions, W × D × H (in) | 27.95x26.57x16.93 |
| Net / gross weight (lb) | 66.80/77.16 |
| Model | OW-P12AC115WF |
|---|---|
| Power supply | 115V, 1Ph, 60Hz |
| Cooling capacity (Btu/h) | 12000 |
| CEER (Btu/h/W) | 10.5 |
| Cooling input (W) | 1140 |
| Cooling current (A) | 11.3 |
| Heating type | Cooling only |
| Refrigerant | R32 |
| Indoor air flow, high / medium / low (CFM) | 276.5 / 250.6 / 220.0 |
| Indoor noise, high / medium / low (dB(A)) | 59 / 56.8 / 55.3 |
| Outdoor noise, high / medium / low (dB(A)) | 68.7/65.3/62 |
| Plug type | LCDI(5-15P) |
| Unit dimensions, W × D × H (in) | 24.21 × 20.28 × 14.53 |
| Packing dimensions, W × D × H (in) | 27.95x26.57x16.93 |
| Net / gross weight (lb) | 74.96/87.52 |
| Model | OW-P12AC230WF |
|---|---|
| Power supply | 208-230V, 1Ph, 60Hz |
| Cooling capacity (Btu/h) | 12000 / 11700 |
| CEER (Btu/h/W) | 10.5 |
| Cooling input (W) | 1140 / 1110 |
| Cooling current (A) | 5.6 / 6.3 |
| Heating type | Cooling only |
| Refrigerant | R32 |
| Indoor air flow, high / medium / low (CFM) | 274.7 / 259.4 / 237.1 |
| Indoor noise, high / medium / low (dB(A)) | 60.2 / 59 / 57.5 |
| Outdoor noise, high / medium / low (dB(A)) | 68.3/66.7/63.9 |
| Plug type | LCDI(6-15P) |
| Unit dimensions, W × D × H (in) | 24.21 × 20.28 × 14.53 |
| Packing dimensions, W × D × H (in) | 27.95x26.57x16.93 |
| Net / gross weight (lb) | 74.52/86.86 |
| Model | OW-P12HS230WF |
|---|---|
| Power supply | 208-230V, 1Ph, 60Hz |
| Cooling capacity (Btu/h) | 12000 / 11700 |
| CEER (Btu/h/W) | 9.5 |
| Cooling input (W) | 1180 / 1160 |
| Cooling current (A) | 6.5 / 7.0 |
| Heating type | Electric heat strip |
| Electric heating capacity (Btu/h) | 10600 / 8600 |
| Electric heating input (W) | 3450 / 2821 |
| Refrigerant | R32 |
| Indoor air flow, high / medium / low (CFM) | 273.5 / 251.8 / 230.6 |
| Indoor noise, high / medium / low (dB(A)) | 61.8 / 60 / 58 |
| Outdoor noise, high / medium / low (dB(A)) | 65.4/63.2/61.1 |
| Plug type | LCDI(6-20P) |
| Unit dimensions, W × D × H (in) | 24.21 × 20.28 × 14.53 |
| Packing dimensions, W × D × H (in) | 27.95x26.57x16.93 |
| Net / gross weight (lb) | 74.96/85.76 |
| Model | OW-P14AC230WF |
|---|---|
| Power supply | 208-230V, 1Ph, 60Hz |
| Cooling capacity (Btu/h) | 14000 / 13600 |
| CEER (Btu/h/W) | 9.5 |
| Cooling input (W) | 1400 / 1360 |
| Cooling current (A) | 7.0 / 7.7 |
| Heating type | Cooling only |
| Refrigerant | R32 |
| Indoor air flow, high / medium / low (CFM) | 280.0 / 264.7 / 245.3 |
| Indoor noise, high / medium / low (dB(A)) | 60.5 / 59.5 / 58 |
| Outdoor noise, high / medium / low (dB(A)) | 69.9/68/65.9 |
| Plug type | LCDI(6-15P) |
| Unit dimensions, W × D × H (in) | 24.21 × 20.28 × 14.53 |
| Packing dimensions, W × D × H (in) | 27.95x26.57x16.93 |
| Net / gross weight (lb) | 75.40/87.74 |
| Model | OW-P14HS230WF |
|---|---|
| Power supply | 208-230V, 1Ph, 60Hz |
| Cooling capacity (Btu/h) | 14000 / 13600 |
| CEER (Btu/h/W) | 9.5 |
| Cooling input (W) | 1430 / 1400 |
| Cooling current (A) | 7.9 / 8.5 |
| Heating type | Electric heat strip |
| Electric heating capacity (Btu/h) | 10600 / 8600 |
| Electric heating input (W) | 3450 / 2821 |
| Refrigerant | R32 |
| Indoor air flow, high / medium / low (CFM) | 272.4 / 251.8 / 232.9 |
| Indoor noise, high / medium / low (dB(A)) | 62.3 / 61.2 / 59.8 |
| Outdoor noise, high / medium / low (dB(A)) | 69.8/67.2/64.8 |
| Plug type | LCDI(6-20P) |
| Unit dimensions, W × D × H (in) | 24.21 × 20.28 × 14.53 |
| Packing dimensions, W × D × H (in) | 27.95x26.57x16.93 |
| Net / gross weight (lb) | 77.38/87.74 |
1-Year Limited Warranty (registration and terms apply).
Manufacturer may change specifications without notice. Always verify electrical and installation details in the current manuals.
The Olmo Through-The-Wall (TTW) air conditioner is a sleek, permanent install that cools efficiently without blocking your windows. Control it two ways: with the included remote or via Smart Connect on your phone.
Comfort & convenience features: Sleep Mode, Timer, Auto Restart, multiple fan speeds, self-evaporative condensate management, compound air filter, LED display, and fresh-air intake.
Models are available in 115V and 208/230V with plug types that include LCDI(5-15P), LCDI(6-15P), and LCDI(6-20P) depending on the unit. Refrigerant is R32 for high efficiency.
Tip: Verify electrical outlet/plug type and wall sleeve compatibility before purchase. See the product’s Energy Guide / User Manual linked in the “Manuals & documents” section.
LCDI(5-15P) plugs.LCDI(6-15P) or LCDI(6-20P) plugs.Designed into the project
Before equipment arrives, make sure the room, connection, and installation plan are ready for it.
Confirm the existing sleeve, wall opening, cabinet fit, and exterior grille. TTW and PTAC formats are not interchangeable.
Confirm voltage, plug or wiring requirements, and the circuit for the exact model. Select the heating configuration your project needs.
Review sleeve and grille add-ons, guest controls, and compatibility. Accessories are sold separately unless the selected configuration states otherwise.

OLMO · CUSTOMER EXPERIENCES