1
/
of
1
OLMO - R410A - 22 - 2 - 3 zones - Outdoor Condenser - Sierra - 208-230V
OLMO Multi-Zone R410A Outdoor Condenser 24,000 BTU (2 Ton)
OLMO Multi-Zone R410A Outdoor Condenser 24,000 BTU (2 Ton)
Regular price
$1,065.78 USD
Regular price
$1,146.00 USD
Sale price
$1,065.78 USD
Shipping calculated at checkout.
Quantity
Couldn't load pickup availability

OLMO Multi-Sierra 24,000 BTU Outdoor Heat Pump — OS-MSR24-230VO
Multi-zone inverter heat pump for 2–3 zones. Up to 22 SEER2 and 12.5 EER2. Designed for Multi-Sierra wall-mount indoor units.
24,000 BTU/h cool & heat 2–3 zones SEER2 up to 22 EER2 up to 12.5 R410A 208–230V, 1Ph, 60Hz
Why pros choose this outdoor unit
- Flexible zoning: supports 2 to 3 indoor units.
- High efficiency: up to 22 SEER2 with inverter technology.
- Cold-climate operation: heating down to −13°F per spec range.
- Simple electrical: MCA 25 A, max fuse 30 A.
At-a-glance
Model
OS-MSR24-230VO
OS-MSR24-230VO
Zones
3-4 Zones
3-4 Zones
Refrigerant
R410A
R410A
Sound
59 dB(A)
59 dB(A)
What’s included
- Outdoor inverter heat pump unit OS-MSR24-230VO
- Owner/installation documentation (per shipment)
Indoor units, line sets, communication cable, and accessories sold separately.
Tech specs
Spec | Details |
---|---|
Model | OS-MSR24-230VO |
System type | Multi-zone inverter heat pump |
Cooling capacity (nom.) | 24,000 BTU/h |
Heating capacity @ 47°F | 24,000 BTU/h |
SEER2 / EER2 (up to) | 22 / 12.5 |
HSPF2-5 / HSPF2-4 | 9.17 / 11.21 |
Refrigerant | R410A |
Refrigerant piping (liq/gas) | 1/4″ / 3/8″ |
Refrigerant precharge | 25 (per spec) |
Additional charge | 0.16 per ft for 1/4″ and 3/8″ liquid lines |
Max pipe length (indiv./total) | 66 ft / 197 ft |
Max height difference | 15 |
Power | 208–230 V, 1-Phase, 60 Hz |
Voltage range | 198–253 V |
MCA / Max fuse | 25 A / 30 A |
Outdoor noise | 59 dB(A) |
Outdoor air flow | 2.35 (per spec) |
Unit dimensions (W×H×D) | 37-3/8 × 33 × 13-3/8 in |
Packing dimensions (W×D×H) | 43-3/4 × 18-1/8 × 36-1/4 in |
Net / Gross weight | 158.7 / 169.5 lb |
Ambient temp (heat / cool) | −13~75.2°F / 14~114.8°F |
Compatible IDUs | OLMO Multi-Sierra wall-mount indoor units (2–3 zones) |
Confirm port count, line sizes, and charging against the submittal and installation manual for your zone mix.
Documents
- Olmo Multi-Sierra Leaflet 2024 (PDF)
- OLMO Catalog 2024 (PDF)
- Multi-SIERRA ODU User & Installation Manual (PDF)
Warranty
- 5-year compressor limited warranty
- 2-year parts limited warranty (licensed HVAC install and registration within 60 days)
FAQs
How many rooms can this support?
Two to three zones when paired with compatible Multi-Sierra wall-mount indoor units.
What refrigerant does it use?
R410A with factory precharge. Add charge per line length as specified.
What electrical protection is required?
MCA 25 A and max fuse 30 A at 208–230 V single phase. Follow local code.
What are the operating temperature ranges?
Heating −13~75.2°F. Cooling 14~114.8°F.
Share