Product Overview
Product Overview
OLMO Multi-Sierra 36,000 BTU Outdoor Heat Pump — OS-MSR36-230VO
Multi-zone From 3 - 4 Zones inverter heat pump with up to 21 SEER2 and 12.5 EER2. Compatible with Multi-Sierra wall-mount indoor units.
Multi-zone Cooling 32,000 BTU/h Heating 36,000 BTU/h @47°F SEER2 up to 21 EER2 up to 12.5 HSPF2-5: 9.12 HSPF2-4: 11.05 R410A 208–230V, 1Ph, 60Hz
Why pros choose this outdoor unit
- Efficient comfort: inverter compressor with up to 21 SEER2.
- Cold-weather capable: heating operation down to −13°F (per spec range).
- Straightforward electrical: MCA 32.2 A, max fuse 50 A.
- Service ready: factory precharge and clear additional charge per line size.
At-a-glance
Model
OS-MSR36-230VO
OS-MSR36-230VO
Zones
3 - 4 Zones
3 - 4 Zones
Refrigerant
R410A
R410A
Sound
59 dB(A)
59 dB(A)
What’s included
- Outdoor inverter heat pump unit OS-MSR36-230VO
- Owner/installation documentation (per shipment)
Indoor units, line sets, communication cable, and accessories sold separately.
Tech specs
| Voltage range (V) | 198~253 |
|---|---|
| System type | Multi-zone unit |
| SEER2 up to | 21 |
| Refrigerant type | R410A |
| Refrigerant piping Liquid/Gas side (inch) | 1/4"/3/8" |
| Packing dimensions (WxDxH) | 43-3/4x18-1/8x47-1/4 |
| Max. pipe length (ft) | 66/246 |
| HSPF2-5 | 9.12 |
| HSPF2-4 | 11.05 |
| EER2 up to | 12.5 |
| Unit Net/Gross weight | 188.5/220.5 |
| Unit dimensions (W*H*D) | 37-3/8x41-3/8x13-3/8 |
| Power source | 208-230V, 1Ph, 60Hz |
| Outdoor Noise Level | 59 |
| Minimum circuit ampacity | 32.2 |
| Max.fuse | 50 |
| Heating Capacity at 47°F | 36,000 |
| COP | 3.37 |
| Cooling Capacity (nominal) | 32,000 |
| Ambient temperature - Heating | -13~75.2 |
| Ambient temperature - Cooling | 14~114.8 |
| Outdoor air flow (CFM) | 3411 |
Verify line sizes, branch kits, and charging against the submittal and installation manual for your exact multi-zone mix.
Documents
Warranty
- 5-year compressor limited warranty
- 2-year parts limited warranty (licensed HVAC install and registration within 60 days)
FAQs
How many rooms can this support?
From 3- 5 zones when paired with compatible Multi-Sierra wall-mount indoor units.
What refrigerant does it use?
R410A with factory precharge. Add charge per line length as specified.
What electrical protection is required?
MCA 32.2 A and max fuse 50 A at 208–230 V single phase. Follow local code.
What are the operating temperature ranges?
Heating −13~75.2°F. Cooling 14~114.8°F.
OLMO · CUSTOMER EXPERIENCES